Manual machine for leak test process

 

 

control box for leak test process

TnPE-L
Machine for air tightness control by sampling.
Manual loading, automatic cycle of test.
Measure electronic and displaying test values.
Desk operator LCD, 20 specific checking routines.
Adjustment height per container type.

   
TnPE-I
Principle of detection  
pressure decay or pressure increase
Technology sensor  
piezoresistive
Response time sensor  
2ms
Range of proving pressure  
-101kPa < > 0kPa
0kPa < > 100kPa
0kPa < > 1MPa
Number of measurement ways  
1 to 4
Typical diameter of detected hole(1)  
0,1mm
Number of programs  
20
Operating modes  
Production
Calibration
Parameter setting
Meters of results  
2 GOOD/BAD meters per program
PC interface (option)  
RS 232 (with Xrecord software)
Print results (option)  
serial printer
Voltage source  
100 to 240 Vac
Electric power  
maximum 100W
   

(1) : the equivalent diameter hole of detectable air leak is related to the allocated search time (but not in a linear way); to detect a diameter of hole 2 times smaller, about 4 times more time is needed.