Leak testing machine in-line, with dynamics heads

 

 

in-line leak tester, dynamic heads

TnPE-CH
Machine for automatic air leak test on production line.
Dynamic sensor heads during the test, fixed on mobile carriage ("Brushless" motorization), which combine the flexibility of linear machines at the great rate of rotating machines.
Electronic measure and displaying test values.
Desk operator LCD, 20 specific checking routines.
Adjustment of height and width per container type.
Frame with or without conveyor, for assembly on present line .

   
TnPE-CH
Principle of detection  
decay pressure
Technology sensor  
piezoresistive
Response time sensor  
2ms
Range of proving pressure  
0kPa <> 100kPa
0kPa <> 1MPa
Number of sensors  
1 to 6
Typical diameter of detected hole(1)  
0,2mm
Number of programs  
20
Operating modes  
Production
Calibration
Parameter setting
Meters of results  
2 GOOD/BAD meters per program
PC interface (option)  
RS 232 (with Xrecord software)
Print results (option)  
serial printer
Voltage source  
240 Vac
or 3x380Vac + N
Electric power  
maximum 500W
Materials frame  
anodic aluminum or stainless 304L
Options  
Control crushing
Control diameter neck
Self calibration
   

(1) : the equivalent diameter hole of detectable air leak is related to the allocated search time (but not in a linear way); to detect a diameter of hole 2 times smaller, about 4 times more time is needed.