Leak testing machine in-line, high frequency

 

 

in-line leak tester, rotating process

TnPE-CA
Leak tester for important rates, with rotary table and embedded heads.
Electronic measure and displaying test values.
Desk operator LCD, 20 specific checking routines.

   
TnPE-CA
Principle of detection  
decay pressure
Technology sensor  
piezoresistive
Response time sensor  
2ms
Range of proving pressure  
0kPa <> 100kPa
0kPa <> 1MPa
Number of sensors  
8 to 30
Typical diameter of detected hole(1)  
0,2mm
Number of programs  
20
Operating modes  
Production
Calibration
Parameter setting
Meters of results  
2 GOOD/BAD meters per program
PC interface (option)  
RS 232 (with Xrecord software)
Print results (option)  
serial printer
Voltage source  
3x380Vac + N
Materials frame  
anodic aluminum or stainless 304L
Options  
Self calibration
   

(1) : the equivalent diameter hole of detectable air leak is related to the allocated search time (but not in a linear way); to detect a diameter of hole 2 times smaller, about 4 times more time is needed.

Coprosud © 2006 - Design by HP